AXIS#.MOTOR.CTF0
Description
This parameter is used to configure the thermal constant of the motor coil, which is the break frequency of a single-pole low-pass filter model of the thermal dynamics of the motor coil.
This parameter, together with AXIS#.MOTOR.IPEAK and AXIS#.MOTOR.ICONT , determine the motor foldback (thermal protection) operating values.
Calculating AXIS#.MOTOR.CTF0
Given a motor coil/winding thermal time constant T in seconds, then:
AXIS#.MOTOR.CTF0 = 1/(2πT)
-
- This parameter is automatically configured for Kollmorgen motors when MOTOR.AUTOSET=1.
Context
For more information see Motor.
Versions
Action | Version | Notes |
---|---|---|
Implemented | 02-00-00-000 |
General Information
Type |
Read/Write |
Units |
mHz |
Range |
0.265 to 16,000 |
Default Value |
10 |
Data Type |
Float |
See Also |
N/A |
Stored in Non Volatile Memory |
Yes |
Variants Supported
All variants are supported.
Fieldbus Information
Fieldbus![]() |
Parameter | Index | Sub-Index | Data Type | Float Scale | Units | Access | PDO Mappable |
---|---|---|---|---|---|---|---|---|
EtherCAT![]() |
AXIS1.MOTOR.CTF0 | 0x500B | 0xE | UDINT | 1000:1 | - | RW | False |
AXIS2.MOTOR.CTF0 | 0x510B | 0xE | UDINT | 1000:1 | - | RW | False |